KNAUF UNIVERSALGRUND
KNAUF UNIVERSALGRUND Price range: 19,37 zł through 70,11 zł
Powrót do produktów
TP 435 B fasady wentylowane
TP 435 B ventilated façades Price range: 30,00 zł through 51,00 zł

KNAUF Therm PRO Parking/Foundation EPS 200 λ 33

504,30 zł

KNAUF Therm PRO Parking/Foundation EPS 200 λ 33 polystyrene boards are manufactured in accordance with the European standard EN 13163:2012 + A1:2015.

410,00 zł / m³
Net price
504,30 zł / m³
Gross price
Insulation calculator – STYROPIAN
How much do you want to insulate (target value)?.
The per-kilometre surcharge will be calculated automatically (later).
You can insulate the following area (m²): –“ m²
Select the number of parcels:
Total (m³):
–“
m² per pack: –“
m³ per pack: –“
Postcode: – (additional charge per km: to be calculated)
Free delivery on orders of 30 m³ or more.
Total value: –“ zł
12 People watching this product now!

Fast delivery

Within Poland

Safety

Careful packaging

Customer support

Contact via chat

Top quality

A trusted brand

Dimensions N/A
Thickness [cm]

1 cm

,

2 cm

,

3 cm

,

4 cm

,

5 cm

,

6 cm

,

7 cm

,

8 cm

,

9 cm

,

10 cm

,

11 cm

,

12 cm

,

13 cm

,

14 cm

,

15 cm

,

16 cm

,

17 cm

,

18 cm

,

19 cm

,

20 cm

,

21 cm

,

22 cm

,

23 cm

,

24 cm

,

25 cm

,

26 cm

,

27 cm

,

28 cm

,

29 cm

,

30 cm

Intended use

Foundation

,

Floor

Lambda

33

Product description

KNAUF Therm PRO Parking/Foundation EPS 200 λ 33

KNAUF Therm PRO Parking/Foundation EPS 200 λ 33 polystyrene boards are manufactured in accordance with the European standard EN 13163:2012 + A1:2015, under which they are designated by the following code:

KNAUF Therm PRO Parking/Foundation EPS 200 λ 33 is a specialist product with high compressive strength, recommended by designers for areas where the permissible live load does not exceed (according to EN 13 163, Annex D.2) 6,000 kg/m²

Application:

  • thermal insulation of floors beneath the floor screed, subject to heavy loads,
  • Thermal insulation for floors on ground level with a floor covering, subject to heavy loads
  • thermal insulation on the load-bearing structure beneath the tiled roof,
  • thermal insulation of flat roofs and roofs suitable for parking,
  • thermal insulation of floors beneath a precast slab sub-base
  • thermal insulation of plinths in external composite thermal insulation systems (BSO)
λ D Thermal conductivity coefficient W/(mK) ≤ 0.033
Edge shape rectangular / milled
Dimensions 1000 x 500 mm, max. dimensions: 4000 x 1200 mm
Compressive stress at 10% relative strain (kPa) CS(10)200 (≥ 200)
Self-extinguishing properties SELF-EXTINGUISHING
Fire reaction class E
Bending strength (kPa) BS 250 (≥ 250)